This paper presents design and implement of wireless clamp-on meter and calibrated with commercial clamp-on meter HIOKI model 3280-10. The results showed that measuring the alternating current on the low-voltage transformer of distribution systems using wireless clamp-on meter photo type. When comparing the alternating current measured by commercial clamp-on meter. The measurement has error between -2.45% to +2.20%, which can be used satisfactorily. Keyword- Clamp-on Meter, Clamp Meter, Wireless Clamp-on Meter